Fan-wall data center

Fan walls supply air horizontally across contained rack rows, without requiring a raised floor.

Cooling approach
Fan-wall cooling with hot-aisle containment
Deployment
Modular halls with room-level air cooling
Solution planning range
Up to 25 kW per cabinet

Overview

Organize the supply and return air paths

Enclosed hot aisles collect server exhaust while fan-wall units circulate cooling air across the rack rows. This horizontal airflow layout does not require a raised floor.

Rack modules

Enclose the hot aisles

Coordinate the rack rows and containment with access doors and maintenance routes.

Room airflow

Use horizontal air distribution

Place the fan walls to serve the rack inlets and receive the contained return air.

Cooling interfaces

Coordinate the site connections

Confirm how the fan walls connect to the facility cooling system and define duty and standby operation.

Reference configuration

Two forty-cabinet modules

Example layout with two enclosed-hot-aisle modules. Confirm whether the four listed fan-wall units serve one module or both during equipment selection.

In this example

Per cabinet in this example
10 kW
Cabinets per module
40
Heat load per module
400 kW
Combined heat load
800 kW

Scroll the table to see all columns

Equipment in this reference configuration
EquipmentModelQuantityDuty / standby
Fan-wall coolingHPS300CW43 + 1

Duty + standby: 2 + 1 means two duty units and one standby unit.

This example is not a fixed bill of materials. Final equipment selection, capacity and redundancy depend on the IT requirements and site operating conditions.

Technology

Inside the system

Horizontal supply air without a raised floor

The fan-wall design uses horizontal, distributed air supply and enclosed hot aisles. A large heat-exchange surface and a low-air-resistance coil support the airflow strategy.

Reference performance comparison
Design featureReference comparison
No raised floor; horizontal distributed supplyUp to 10% lower cooling-system cost
Large heat-exchange area and low-resistance coil50% lower fan power consumption
Cooling capacity per unit of width66% increase
Computing capacity30% increase

Comparison equipment, design baselines and test conditions are not specified for these reference percentages. Validate performance against the proposed layout and selected equipment.

Source: slide 10

Related equipment

Explore the product families

All products

Plan your project

Start with your requirements

Share your deployment needs to discuss the right configuration.

Talk to our team

Useful details to include

  • Rack count, actual heat loads and module layout
  • Supply and return paths, containment and service access
  • Facility cooling connections and required standby capacity