Cabinets & pods
Integrated cabinets and enclosed computing pods for branch sites, edge nodes and compact IT spaces.

Edge data center
Integrated cabinets with power, cooling, monitoring and fire protection for branch offices and local IT.
- Cooling
- Refrigerant-pump in-row cooling
- IT load
- Up to 15 kW per cabinet

AI computing pod
An enclosed computing pod separates hot and cold aisles around a compact row of racks.
- Cooling
- In-row cooling with dual containment
- IT load
- Up to 30 kW per cabinet
Data halls
Rack-row and room-scale systems using in-row, rear-door, fan-wall or liquid cooling.

Modular air-cooled data center
Contained rack modules use in-row cooling and shared outdoor units for air-cooled data halls.
- Cooling
- Heat-pipe in-row cooling
- IT load
- Up to 25 kW per cabinet

Rear-door-cooled data center
Rear-door heat exchangers remove heat at each rack exhaust, supporting higher-density air-cooled computing rows.
- Cooling
- Heat-pipe rear-door heat exchangers
- IT load
- Up to 60 kW per rack

Fan-wall data center
Fan walls supply air horizontally across contained rack rows, without requiring a raised floor.
- Cooling
- Fan-wall cooling with hot-aisle containment
- IT load
- Up to 25 kW per cabinet

Liquid-cooled modular data center
Liquid-cooled racks connect through CDUs to outdoor dry coolers, with separate cooling for residual air heat.
- Cooling
- CDUs, dry coolers and residual air cooling
- IT load
- 100 kW+ per cabinet
Containerized systems
Factory-integrated data center containers with air or liquid cooling, delivered for connection to site utilities.

Air-cooled container data center
A factory-integrated container combines IT racks, power and refrigerant-pump in-row cooling for deployment on site.
- Cooling
- Refrigerant-pump in-row cooling
- IT load
- Up to 25 kW per cabinet

Liquid-cooled container data center
A prefabricated container integrates liquid-cooled racks, CDUs and residual air cooling, with outdoor dry coolers.
- Cooling
- CDUs, dry coolers and residual air cooling
- IT load
- 100 kW+ per cabinet
Rack and cabinet loads are planning ranges. Reference configurations are examples; final equipment selection depends on your IT requirements and site conditions.
Beyond the equipment
Factory integration & delivery
Three modules. One integrated platform.
The prefabricated platform brings IT Computing, Cooling & HVAC, and Power & Distribution together. Enclosures, aisles, power and cooling are pre-installed and commissioned at the factory under full operating conditions.
- IT Computing — racks, computing space and aisle arrangements coordinated within the enclosure.
- Cooling & HVAC — cooling equipment and connections integrated around the computing load.
- Power & Distribution — power supply and distribution integrated with the IT and cooling systems.
- Factory integration avoids secondary on-site integration, wet works and scattered installation, leaving external utility interfaces such as water and power to connect.
Manufacturing and site preparation in parallel
Factory fabrication can run alongside site civil works. Standardized workshop production supports controlled quality, while modular delivery allows capacity to expand from small installations to larger campuses with less scattered work on site.
- Fast deployment — coordinate off-site manufacturing with the site construction programme.
- Controlled quality — standardize fabrication, pre-installation and factory commissioning.
- Flexible expansion — add modules as computing demand grows.
- Reduced site work — minimize on-site assembly as part of a green, low-carbon delivery approach.

| Construction approach | Reference figure |
|---|---|
| Traditional construction | 20 months |
| Prefabricated modular construction | Less than 12 months |
| Delivery efficiency improvement | 40% |
Applications across the computing estate
- AI computing clusters
- IDC computing campuses
- Edge computing nodes
- Government and smart-city infrastructure
- Finance, healthcare and education
- Legacy data-center upgrades
- Emergency and disaster-recovery deployments
- Industrial and energy outdoor sites
Engineering reference
Shared air-cooling architecture
Cooling for the IT room and supporting spaces
The air-cooled portfolio covers cabinet installations, modular halls and rear-door systems, as well as the battery and power-distribution rooms that support them.

| Application | System combination |
|---|---|
| MetaRack cabinet data center | Refrigerant-pump modular condenser + in-row precision AC + MetaRack cabinets |
| Single-row server racks | Multi-split refrigerant unit + heat-pipe rear-door AC + rack row |
| MetaRow modular data center | Multi-split refrigerant unit + heat-pipe in-row AC + MetaRow module |
| Battery room | Cool-smart refrigerant-pump precision air conditioning |
| Power-distribution room | Cybermaster refrigerant-pump room precision air conditioning |