Plan your infrastructure

Data center solutions

Compare the physical layout and cooling approach for your site. Each system includes an illustrated design and a reference equipment configuration.

Cabinets & pods

Integrated cabinets and enclosed computing pods for branch sites, edge nodes and compact IT spaces.

Integrated cabinet row connected to outdoor refrigerant-pump cooling units

Edge data center

Integrated cabinets with power, cooling, monitoring and fire protection for branch offices and local IT.

Cooling
Refrigerant-pump in-row cooling
IT load
Up to 15 kW per cabinet
Coolnet computing pod with an enclosed cabinet row and integrated cooling

AI computing pod

An enclosed computing pod separates hot and cold aisles around a compact row of racks.

Cooling
In-row cooling with dual containment
IT load
Up to 30 kW per cabinet

Data halls

Rack-row and room-scale systems using in-row, rear-door, fan-wall or liquid cooling.

Contained modular data-center rows connected to shared outdoor cooling units

Modular air-cooled data center

Contained rack modules use in-row cooling and shared outdoor units for air-cooled data halls.

Cooling
Heat-pipe in-row cooling
IT load
Up to 25 kW per cabinet
Rear-door heat exchangers connected to an outdoor cooling unit by supply and return pipework

Rear-door-cooled data center

Rear-door heat exchangers remove heat at each rack exhaust, supporting higher-density air-cooled computing rows.

Cooling
Heat-pipe rear-door heat exchangers
IT load
Up to 60 kW per rack
Horizontal supply air and enclosed hot-aisle return paths serving modular rack rows

Fan-wall data center

Fan walls supply air horizontally across contained rack rows, without requiring a raised floor.

Cooling
Fan-wall cooling with hot-aisle containment
IT load
Up to 25 kW per cabinet
Liquid-cooled modular data center connected to a CDU and outdoor dry cooler

Liquid-cooled modular data center

Liquid-cooled racks connect through CDUs to outdoor dry coolers, with separate cooling for residual air heat.

Cooling
CDUs, dry coolers and residual air cooling
IT load
100 kW+ per cabinet

Containerized systems

Factory-integrated data center containers with air or liquid cooling, delivered for connection to site utilities.

Prefabricated data-center enclosure shown with Coolnet branding

Air-cooled container data center

A factory-integrated container combines IT racks, power and refrigerant-pump in-row cooling for deployment on site.

Cooling
Refrigerant-pump in-row cooling
IT load
Up to 25 kW per cabinet
Cutaway illustration of a containerized computing module with liquid-cooling pipework

Liquid-cooled container data center

A prefabricated container integrates liquid-cooled racks, CDUs and residual air cooling, with outdoor dry coolers.

Cooling
CDUs, dry coolers and residual air cooling
IT load
100 kW+ per cabinet

Rack and cabinet loads are planning ranges. Reference configurations are examples; final equipment selection depends on your IT requirements and site conditions.

Beyond the equipment

Factory integration & delivery

Download full presentation PPTX · 23 MB

Three modules. One integrated platform.

The prefabricated platform brings IT Computing, Cooling & HVAC, and Power & Distribution together. Enclosures, aisles, power and cooling are pre-installed and commissioned at the factory under full operating conditions.

  • IT Computing — racks, computing space and aisle arrangements coordinated within the enclosure.
  • Cooling & HVAC — cooling equipment and connections integrated around the computing load.
  • Power & Distribution — power supply and distribution integrated with the IT and cooling systems.
  • Factory integration avoids secondary on-site integration, wet works and scattered installation, leaving external utility interfaces such as water and power to connect.

The required utilities, site works and commissioning scope depend on the selected cooling system and project interfaces.

Source: slide 1

Manufacturing and site preparation in parallel

Factory fabrication can run alongside site civil works. Standardized workshop production supports controlled quality, while modular delivery allows capacity to expand from small installations to larger campuses with less scattered work on site.

  • Fast deployment — coordinate off-site manufacturing with the site construction programme.
  • Controlled quality — standardize fabrication, pre-installation and factory commissioning.
  • Flexible expansion — add modules as computing demand grows.
  • Reduced site work — minimize on-site assembly as part of a green, low-carbon delivery approach.
Original schedule comparison of traditional and prefabricated data-center construction
Illustrative construction schedule from the source presentationView full size
Reference delivery comparison
Construction approachReference figure
Traditional construction20 months
Prefabricated modular constructionLess than 12 months
Delivery efficiency improvement40%

Reference figures, not a committed project schedule. The 40% efficiency calculation and the unit of the chart's 0–9 axis are not defined. Actual delivery depends on land, design, approvals, site conditions and commissioning.

Source: slide 2

Applications across the computing estate

  • AI computing clusters
  • IDC computing campuses
  • Edge computing nodes
  • Government and smart-city infrastructure
  • Finance, healthcare and education
  • Legacy data-center upgrades
  • Emergency and disaster-recovery deployments
  • Industrial and energy outdoor sites
Source: slide 2

Engineering reference

Shared air-cooling architecture

Explore the cooling technology

Cooling for the IT room and supporting spaces

The air-cooled portfolio covers cabinet installations, modular halls and rear-door systems, as well as the battery and power-distribution rooms that support them.

System illustration connecting cabinet rows, modular data halls and rear-door cooling to outdoor equipment
System illustrationView full size
Air-cooled system combinations
ApplicationSystem combination
MetaRack cabinet data centerRefrigerant-pump modular condenser + in-row precision AC + MetaRack cabinets
Single-row server racksMulti-split refrigerant unit + heat-pipe rear-door AC + rack row
MetaRow modular data centerMulti-split refrigerant unit + heat-pipe in-row AC + MetaRow module
Battery roomCool-smart refrigerant-pump precision air conditioning
Power-distribution roomCybermaster refrigerant-pump room precision air conditioning
Source: slide 3